Lelit
Brew Switch / Control Input Failure
Machine does not start a brew cycle when the brew button is pressed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty brew microswitch or button, Broken wire from switch to control board, Failed input circuit on main board, Software lockout due to low water
How to Fix / Troubleshooting
Safety first: Unplug before accessing switches or boards.
- Check water and alarms: Ensure the water tank is full and correctly seated and that no water-level alarm is active.
- Test other functions: See if steam or hot water functions work. If only brew is affected, suspect the brew switch circuit.
- Inspect brew button: On panel-button models, remove the front panel and check the brew button PCB for cracks or loose connectors.
- Test microswitch (lever models): On lever-operated Lelits, verify that the lever actuates the microswitch. Adjust or replace the brew microswitch if it does not click reliably.
- Board input: If the switch works but the board does not respond, the main control board may need service.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Brew Microswitch / Brew Button PCB