Steam Boiler Not Reaching Pressure
No steam pressure; steam wand only emits water or very weak steam.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Steam boiler not heating due to failed element, Incorrect PID or pressurestat setting, Faulty steam boiler thermostat, Scale buildup reducing heat transfer
How to Fix / Troubleshooting
Safety first: Turn OFF, unplug, and allow cooling before internal checks.
- Check pressure gauge: On models with a steam pressure gauge, verify if it rises to the normal range (typically around 1–1.5 bar). If it stays near zero, the boiler is not heating.
- Verify steam mode: Ensure the steam function is enabled and that the machine has had enough time (10–15 minutes) to build pressure.
- Inspect heating circuit: Follow the steps in the general heating failure section to test the steam boiler element and thermostat.
- Descale steam boiler: If the boiler heats but steam is weak, heavy scale may be insulating the element. Perform a descaling cycle focusing on the steam boiler, following Lelit’s guidelines.
- Check steam tip: Remove and clean the steam wand tip; blocked holes can make steam appear weak.