ERR6
Magimix Brew Group Position / Drive Motor Fault (automatic capsule models)

Display shows ERR6 and the machine will not complete a brew cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Brew group jammed by capsule, Brew group drive motor failure, Position sensor or microswitch fault, Gear train obstruction or broken gear

How to Fix / Troubleshooting

Safety first: Unplug the machine before inserting hands into the capsule area.

  • Remove stuck capsule: Open the capsule lever fully. Check for a crushed or misaligned capsule in the brewing chamber. Remove any capsule fragments or foil pieces.
  • Clean the capsule area: Use a soft brush and a damp cloth to remove coffee grounds around the brew head and capsule slide. Do not use sharp tools that could damage seals.
  • Manually reset the brew group (if accessible): On some Magimix capsule machines, you can gently move the brew carriage back to its home position by hand once the machine is unplugged. Do not force it; if it is solidly stuck, stop.
  • Power reset: Plug the machine back in, close the lever, and turn it on. Allow it to run its self-test. If ERR6 clears, run a rinse cycle before brewing again.

If the error persists, the brew group motor, gears, or position sensor may be defective and require professional service.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Brew Group Drive Motor
Check Price on Amazon