F8
Miele
Steam Boiler / Steam Temperature Sensor Fault
Machine shows F8; steam or hot water functions may not work correctly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC sensor on steam boiler, open thermal fuse on steam boiler, wiring fault to steam temperature sensor, scaled steam boiler causing overheating
How to Fix / Troubleshooting
Safety first: Unplug the machine and allow the steam boiler to cool completely. Steam circuits are under pressure and can cause burns.
Basic actions:
- Run a full descaling cycle using Miele descaling tablets to remove limescale from the steam circuit.
- Ensure the milk system and steam nozzle are clean and not blocked.
Technical steps:
- Access the steam boiler assembly inside the machine.
- Locate the NTC temperature sensor and thermal fuse/thermostat on the steam boiler.
- Check wiring and connectors for damage or loose contacts.
- Measure the NTC resistance at room temperature and compare to specifications; replace if out of range.
- Test the thermal fuse for continuity; replace if open.
Resolution:
- Replace the faulty NTC sensor or thermal fuse with the correct Miele part.
- If sensors and fuses are good but F8 persists, the control board's temperature input may be defective and should be serviced by a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Steam Boiler NTC Sensor / Thermal Fuse
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements