Morphy Richards Low Voltage to Logic Circuit / Memory Retention Issue

Clock or timer loses time or resets randomly on digital models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Power supply instability on PCB, Faulty backup capacitor, Loose mains connection, Control PCB fault

How to Fix / Troubleshooting

Safety first: Unplug before opening the housing.

  • Direct wall connection: Plug the coffee maker directly into a wall outlet, avoiding extension leads that may cause voltage drops.
  • Power cycle: Unplug for 5 minutes, then reset the clock and observe if it holds time.
  • Inspect PCB (advanced): Remove the base and look for bulging electrolytic capacitors on the control PCB, especially near the low-voltage supply section.
  • Replace PCB or capacitors: If capacitors are visibly damaged, they or the entire PCB should be replaced.

If the timer continues to reset, the control PCB is likely failing and should be replaced.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon