Morphy Richards No Power / Open Circuit

Coffee maker does not power on at all, no lights or display.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on PCB, Faulty power switch, Damaged mains cord, Failed main control PCB

How to Fix / Troubleshooting

Safety first: Ensure the appliance is unplugged before any inspection. Do not work on live circuits.

  • Check outlet and RCD: Test the wall socket with another appliance and reset any tripped RCD or breaker.
  • Inspect power cord: Look for cuts, kinks, or burn marks on the Morphy Richards power cord. If damaged, replace the cord set.
  • Test power switch: Toggle the main power switch several times. On some models, the rocker switch can stick; gently work it back and forth.
  • Internal fuse (advanced): Remove the base or rear cover to access the main PCB. Look for a small glass or ceramic fuse. If blown, replace only with the same rating. If it blows again immediately, there is a deeper fault (heater or PCB short) requiring professional repair.

If there is still no power after these checks, the main control PCB or power supply section is likely faulty and should be replaced by a technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB / Internal Fuse
Check Price on Amazon

We may earn a commission from links on this page.