Morphy Richards Restricted Pump Output / Scale

Espresso models: Pump is very loud and vibrates, but only a small trickle of coffee comes out.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Scale in pump or thermoblock, Partially blocked group head, Airlock in pump, Worn pump valves

How to Fix / Troubleshooting

Safety first: Unplug before removing covers; normal descaling can be done with power off until the cycle is started.

  • Run hot water only: Without coffee in the portafilter, run hot water through the group head to see if flow improves.
  • Descale thoroughly: Use a descaler suitable for espresso machines and run multiple cycles through the espresso circuit.
  • Bleed air: Run water through the steam wand and group head alternately to clear air from the pump.
  • Clean group head: Remove and clean the shower screen and gasket area.

If the pump remains loud with poor flow, the vibration pump may be worn and should be replaced.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Vibration Pump / Thermoblock
Check Price on Amazon