ERR
Mr. Coffee General Control Board / Sensor Fault

Display shows “ERR” or “ERROR” and unit will not start a brew cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Firmware glitch in control PCB, Faulty temperature sensor on heating element, Shorted keypad or stuck button, Internal moisture on control board connectors

How to Fix / Troubleshooting

Safety first: Unplug the coffee maker before any inspection.

  • Power reset:
    • Unplug the unit for at least 10 minutes to allow capacitors to discharge.
    • Plug back in and attempt to set time and start a simple brew cycle.
  • Check for stuck buttons:
    • Press each button on the control panel several times to ensure none are stuck.
    • Wipe the panel with a slightly damp cloth and dry thoroughly.
  • Inspect for moisture:
    • If the unit was recently overfilled or exposed to steam, allow it to dry for several hours in a warm, dry area.

If the error returns immediately after reset, the control board or temperature sensor is likely faulty. Replacement of the control PCB or sensor requires opening the housing and should be performed by a qualified technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Control PCB
Check Price on Amazon