Green light on, machine shuts off mid-brew
Nescafé Dolce Gusto
Overcurrent or thermal protection trip
Machine starts brewing but stops and powers off before the beverage is complete.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partially blocked thermoblock, Failing vibration pump drawing excess current, Faulty power supply board, Overheating due to poor ventilation
How to Fix / Troubleshooting
Safety: Unplug the machine and allow it to cool for 20–30 minutes.
- Check ventilation: Ensure the machine has space around it and is not enclosed in a cabinet during use.
- Clean and descale: Clean the injector needle and capsule holder, then perform a full descaling cycle to reduce load on the pump and heater.
- Test with water only: After cooling and descaling, run a plain hot-water cycle without a capsule to see if it completes.
If the machine still shuts off mid-brew, an internal electrical fault (pump, heater, or control board) is likely and should be diagnosed by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon