Low Brew Temperature
Coffee is not hot enough even immediately after brewing
Advertisements
Possible Causes
Scale buildup in thermoblock, Faulty NTC sensor reading high, Control board temperature calibration drift, User not preheating cup
How to Fix / Troubleshooting
User-level steps:
- Preheat cups with hot water before brewing.
- Run a blank shot (without capsule) to warm the brew path.
- Perform a full descale to improve heat transfer.
Technical steps:
- Check the NTC sensor resistance and replace if out of spec.
- If temperature remains low despite a good sensor and clean thermoblock, the control board may be under-driving the heater and should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Thermoblock / NTC Sensor