Nespresso Low Extraction Pressure or Incorrect Flow

Coffee tastes weak or watery compared to usual

Advertisements

Possible Causes

Worn pump producing low pressure, Scale buildup reducing temperature, Worn brew head gasket causing pressure loss, Incorrect capsule type or stale capsules

How to Fix / Troubleshooting

User-level steps:

  • Ensure you are using genuine, fresh Nespresso capsules of the correct type for your machine.
  • Descale the machine to restore proper temperature and flow.
  • Run a rinse cycle before brewing to preheat the system.

Technical steps:

  • Inspect and replace the brew head gasket if it is worn.
  • If pressure remains low, test and replace the ULKA pump if necessary.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Brew Head Gasket / ULKA Pump
Check Price on Amazon