ERR5
OXO
Real‑Time Clock / Timer Circuit Fault
Display shows “ERR5” and the timer or clock functions do not operate correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Firmware error in control board, Power surge corrupting timer memory, Failed clock crystal on PCB, Moisture damage to control electronics
How to Fix / Troubleshooting
Safety first: Unplug the coffee maker before performing any extended resets.
- Factory reset: Consult the user manual for the specific button combination to reset the clock and timer settings (often holding the clock and power buttons together). Perform the reset and reprogram the time.
- Power isolation: Unplug the unit for at least 30 minutes to fully discharge internal components, then plug back in and set the clock again.
- Avoid power strips: Plug the coffee maker directly into a wall outlet instead of a power strip with other high‑load appliances to reduce electrical noise and surges.
- Persistent error: If ERR5 remains and the timer cannot be set, the control board’s clock circuit is likely damaged. Replacement of the main PCB is required and should be done by a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements