Proctor Silex Brew Start / Control Logic Failure

Coffee maker powers on but will not start brewing when the BREW or ON button is pressed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty brew switch or start button, Defective control PCB relay, Broken internal wiring to heater, Lid or carafe safety switch not engaging (on some models)

How to Fix / Troubleshooting

Safety first: Unplug the unit before opening any covers.

  • Confirm setup: Ensure the carafe is fully seated on the warming plate and the brew basket is properly installed. Some Proctor Silex models have interlocks that prevent brewing if parts are misaligned.
  • Try manual mode: On programmable models, cancel any timer settings and press the manual BREW/ON button. Wait a full minute to see if brewing starts.
  • Inspect start button: If the button feels stuck or does not click, the switch may be worn. Disassemble the control panel and test the switch for continuity when pressed.
  • Check lid/carafe switch: If your model has a lid or carafe sensor, verify that the actuator tab is not broken and that the switch clicks when engaged.
  • Advanced: If switches test good, the control PCB or heater relay may have failed. Replacement of the control board is required in that case.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Brew Start Switch
Check Price on Amazon

We may earn a commission from links on this page.