Proctor Silex
Under-Extraction / Incorrect Brew Temperature or Flow
Coffee tastes weak or watery even when using the same amount of coffee as before.
Advertisements
Possible Causes
Water not reaching optimal temperature due to weak heater, Water flowing too quickly through grounds, Incorrect grind size (too coarse), Spray head not distributing water evenly
How to Fix / Troubleshooting
Safety first: Unplug before any internal inspection.
- Check coffee and filter: Use medium grind coffee and ensure the filter is properly seated.
- Descale: Mineral buildup can affect temperature and flow. Run a full descaling cycle with vinegar and water, then rinse with clean water.
- Inspect spray head: Remove and clean the spray head to ensure all holes are open, promoting even saturation of the grounds.
- Evaluate temperature: If coffee is lukewarm right after brewing, the heater may not be reaching proper temperature, indicating a failing heating element or thermostat.
- Adjust ratio: If hardware is functioning, increase the coffee-to-water ratio slightly to compensate.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements