E4
Proctor Silex Internal Temperature Too High / Sensor Out of Range

Digital Proctor Silex coffee maker shows E4 and shuts off shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked internal ventilation around heater, Heavy scale buildup in heater tube, Faulty NTC temperature sensor reading high, Defective main control PCB temperature circuit

How to Fix / Troubleshooting

Safety first: Unplug the unit and let it cool fully before any disassembly.

  • Clean exterior vents: If your model has bottom or side vents, ensure they are not blocked by debris, dust, or being pushed tightly against a wall.
  • Descale the system: Fill the reservoir with a 1:1 mix of white vinegar and water. Run a brew cycle until halfway, then pause for 20–30 minutes to let the solution soak. Resume the cycle, then run 2–3 full cycles of clean water to flush.
  • Inspect sensor placement: Remove the bottom cover and locate the NTC sensor clipped to the heater or warming plate. Make sure it is firmly attached and not hanging loose, which can cause false high readings.
  • Check wiring: Inspect the sensor wires for damage or melted insulation. Reseat the connector on the control board.
  • Next steps: If E4 persists after descaling and wiring checks, the sensor or control board is likely defective. Replacement of the NTC sensor may resolve the issue; if not, the main control PCB may need replacement or the unit replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements