Proctor Silex
Stuck Indicator Circuit / Switch Fault
Indicator light stays on even when the coffee maker is switched off.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or shorted indicator LED circuit on PCB, Faulty power switch contacts, Miswired internal connections after repair
How to Fix / Troubleshooting
Safety first: Unplug the unit before inspection.
- Confirm function: Verify that the heater and warming plate are actually off (cool to the touch) despite the light being on.
- Inspect switch: Test the power switch for proper operation and continuity. Replace if it does not fully open when off.
- Check wiring: Ensure the indicator light is wired correctly and not receiving constant power due to miswiring.
- PCB issue: If wiring and switch are correct, the control PCB may have a stuck transistor or trace feeding the LED; replacement of the board is the typical fix.
Advertisements
Repair Difficulty
Medium
3/5