Possible Causes
Faulty brew switch or keypad button, Broken microswitch behind lever (on lever‑actuated groups), Loose wiring to brew switch, Control board input failure
How to Fix / Troubleshooting
Safety: Unplug before accessing the control panel or switches.
- Test other functions: Verify that steam and hot water functions work. If only brew is affected, suspect the brew switch circuit.
- Inspect brew switch: Remove the front panel and check the brew button or lever microswitch. Test for continuity when pressed. Replace if defective.
- Check wiring: Ensure the switch wires are firmly connected to the main board and not broken.
- Control board: If the switch tests good but the board does not respond, the input channel on the control board may be faulty and require replacement.