Rocket Espresso
Steam Pressure Gauge / Sensing Line Fault
Steam pressure gauge does not move or shows incorrect readings, even though steam output seems normal.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked gauge capillary line with scale, Faulty steam pressure gauge, Leak in sensing line, Loose gauge fitting
How to Fix / Troubleshooting
Safety first: Turn off and unplug the machine. Allow the boiler to cool and depressurize before working on the gauge line.
- Visual inspection: Check the copper or stainless capillary tube from the boiler to the gauge for kinks or damage.
- Tighten fittings: Ensure all gauge fittings are snug to prevent leaks and air ingress.
- Clear blockage (advanced): Remove the capillary tube and soak it in descaling solution to dissolve internal scale, then flush thoroughly.
- Replace gauge: If the gauge remains unresponsive or sticks, replace it with a Rocket-compatible steam pressure gauge.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Steam Pressure Gauge
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements