Russell Hobbs Brew Start Control / Input Fault

Coffee maker powers on but will not start brewing when the brew button is pressed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty brew button on control panel, Loose ribbon cable to PCB, Control PCB logic failure, Safety interlock (carafe or lid) not engaged

How to Fix / Troubleshooting

Safety first: Unplug the unit before opening any covers.

  • Check safety interlocks: Ensure the carafe is fully seated, the filter basket is closed, and any top lid is properly latched. Many Russell Hobbs models will not start if these are open.
  • Try different modes: Attempt manual brew instead of timer, or vice versa, to see if any mode responds.
  • Panel cleaning: Wipe the control panel with a slightly damp cloth and dry it. Do not allow moisture to seep into the buttons.
  • Inspect ribbon cable: If accessible, remove the top cover and reseat the ribbon cable between the keypad/display board and main PCB.
  • If the brew button still does not respond: The keypad PCB or main control PCB may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Keypad / Control Panel PCB
Check Price on Amazon