Restricted Brew Path / Over-Extraction
Weak coffee flow or shots take much longer than usual to pour
Advertisements
Possible Causes
Clogged shower screen, Dirty group head passages, Excessively fine grind or overdosing, Partially blocked filter basket
How to Fix / Troubleshooting
Safety: Allow the group head to cool before disassembly.
- Adjust coffee preparation:
- Use a slightly coarser grind and reduce dose to recommended levels.
- Ensure even tamping and avoid overfilling the basket.
- Clean shower screen:
- Remove the group head shower screen and screw.
- Soak in hot water with espresso cleaner, then scrub and rinse.
- Backflush (if supported): Use a blind filter and cleaning tablet to backflush the group head and solenoid.
- Inspect filter baskets: Replace worn or clogged filter baskets if holes are blocked with coffee oils.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Group Head Shower Screen
Check Price on Amazon