Possible Causes

Clogged pod holder filter, scale in brew head outlet, partially blocked flow meter, incorrect cup size selection

How to Fix / Troubleshooting

Safety first: Unplug the machine and allow it to cool before disassembling the pod holder.

  • Clean pod holder: Remove the pod holder and rinse thoroughly. Use a soft brush or pin to clear the tiny holes in the metal filter.
  • Clean brew head: Wipe the rubber seal and outlet area. Remove any coffee residue.
  • Descale: Run a full descaling cycle to clear internal restrictions.
  • Check settings: Ensure you are pressing the correct 1‑cup or 2‑cup button and that any programmable volume settings are not reduced.