Sunbeam Insufficient Extraction / Low Brew Temperature

Brewed coffee is weak or watery even when using normal amounts of coffee grounds.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Heater not reaching proper temperature, Thermostat opening too early, Excessively coarse grind, Incorrect brew strength setting

How to Fix / Troubleshooting

Safety first: Allow the unit to cool before internal inspection. Unplug during any disassembly.

  • 1. Adjust coffee and grind
    • Use a medium grind suitable for drip coffee makers.
    • Increase the amount of coffee grounds slightly if needed.
  • 2. Check brew strength setting
    • On models with a strength selector, choose a stronger setting or "bold" mode.
  • 3. Descale the unit
    • Scale buildup can reduce heating efficiency; run a full descale cycle.
  • 4. Test brew temperature (advanced)
    • Run a brew cycle with water only and measure the temperature of the water entering the carafe; it should typically be around 90–96°C (194–205°F).
    • If significantly lower, the heater or thermostat may be faulty.
  • 5. Replace heater or thermostat
    • If the unit cannot reach proper temperature after descaling, replace the heating element or thermostat assembly.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heating Element and Thermostat Assembly
Check Price on Amazon