E08
Tefal
Main Control Board / Power Supply Error
Machine shows E08 and immediately stops; no pump or heater activity is heard.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Internal low-voltage power supply failure, Shorted component on PCB, Corroded board connectors, Surge-damaged microcontroller
How to Fix / Troubleshooting
Safety first: Unplug the coffee maker. Work on electronic boards only if you are experienced; otherwise, contact a service center.
Steps:
- Check outlet and cord: Verify the wall outlet works with another appliance. Inspect the power cord and plug for damage.
- Power reset: Leave the machine unplugged for at least 15 minutes to discharge internal capacitors. Reconnect and test.
- Inspect for moisture: Remove the housing and check for signs of water ingress around the PCB. Dry any moisture with a soft cloth and allow the unit to air dry for several hours before retesting.
- Visual PCB inspection: Look for burnt components, bulging capacitors, or darkened areas on the control board. Check that all connectors are fully seated.
- Do not bypass safety components: If fuses or protective components on the board are blown, they indicate a fault. Replacing the entire board is usually safer than attempting component-level repair without proper tools.
- Reassemble: If no obvious issues are found and E08 persists, the control board is likely defective and should be replaced with the correct Tefal spare part.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements