Tristar Steam Circuit Failure

Steam wand (on combo coffee/espresso Tristar models) does not produce steam.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked steam nozzle, Scale in steam channel of thermoblock, Faulty steam selector valve, Failed steam thermostat

How to Fix / Troubleshooting

Safety first: Unplug and allow the unit to cool completely before working on the steam system.

  • Clean nozzle: Remove the steam wand tip and soak it in hot water. Use a pin to clear any milk residue from the holes.
  • Descale: Run a descaling cycle focusing on the steam function if your Tristar model supports it. Otherwise, run several cycles while activating the steam mode.
  • Check selector valve (advanced): Inspect the steam selector knob and internal valve for proper movement. Replace if seized or leaking.

Note: If the boiler heats but no steam exits, a blockage or valve fault is likely.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Steam Wand and Steam Selector Valve
Check Price on Amazon