Zwilling Milk Suction / Air Intake Blockage

Milk frother does not draw milk properly; milk remains in container and only steam or hot water comes out.

Advertisements

Possible Causes

Blocked milk suction tube, Clogged air intake hole on frother, Hardened milk residue in frothing head

How to Fix / Troubleshooting

Safety: Allow the frother to cool before disassembly.

  • Disassemble frother: Remove all detachable parts of the milk frother (nozzle, suction tube, air intake cap).
  • Soak components: Soak in warm water with milk system cleaner for at least 15 minutes.
  • Clear air holes: Use a fine needle to clear the small air intake holes.
  • Inspect suction tube: Replace the tube if it is cracked, hardened, or discolored.
  • Reassemble and test: Ensure all parts are correctly assembled and firmly attached before testing with cold milk.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Milk Frother Assembly / Milk Suction Tube
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements