Beko Brushroll Imbalance / Nozzle Mechanical Fault

Cordless vacuum produces excessive vibration and rattling when using the motorised floor head, but runs smoothly without it.

Advertisements

Possible Causes

Brushroll bent or warped, Debris lodged in brushroll cavity, Worn brushroll bearings, Loose floor head housing screws

How to Fix / Troubleshooting

Safety first: Remove the battery and detach the floor head.

  • 1. Remove and inspect brushroll: Take out the brushroll and roll it on a flat surface. If it wobbles, it is bent and should be replaced.
  • 2. Clean cavity: Remove any stones, hard debris, or buildup inside the nozzle housing that could cause imbalance.
  • 3. Check bearings: Spin the brushroll ends by hand. If rough or noisy, replace the brushroll or bearing caps.
  • 4. Tighten screws: Inspect the underside of the floor head and tighten any loose screws holding the housing together.
  • 5. Replace head if needed: If vibration persists, replace the complete motorised floor nozzle.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Motorised Floor Nozzle
Check Price on Amazon