Beko
Exhaust Direction / Seal Issue
Cordless vacuum’s exhaust air blows out sideways or backwards more than usual, stirring up dust instead of capturing it.
Advertisements
Possible Causes
Missing or misfitted exhaust grille, Damaged exhaust ducting, Incorrect assembly after cleaning, Cracked rear housing
How to Fix / Troubleshooting
Safety first: Remove the battery before inspecting the exhaust area.
- 1. Check exhaust grille: Ensure the rear exhaust grille or cover is present and clipped in correctly.
- 2. Inspect for gaps: Look for gaps between the exhaust housing and main body that could redirect airflow.
- 3. Reassemble correctly: If the unit was recently disassembled, verify that all panels and seals are correctly aligned and screwed down.
- 4. Replace damaged housing: If the rear housing is cracked or warped, replace it to restore proper exhaust direction.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Rear Exhaust Housing
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements