Beko
Excessive Dust Load / Cyclone Inefficiency
Cordless vacuum’s filters become dirty very quickly and clog after only a short period of use.
Advertisements
Possible Causes
Cyclone assembly partially blocked, Damaged cyclone cones or mesh, Missing internal seals in cyclone, Very fine dust environment (e.g., renovation work)
How to Fix / Troubleshooting
Safety first: Remove the battery before servicing the cyclone and filters.
- 1. Deep clean cyclone: Remove the cyclone assembly and thoroughly clean all cones and mesh screens with a soft brush. Ensure all dust passages are clear.
- 2. Inspect for damage: Check for cracks or missing parts in the cyclone that could reduce separation efficiency.
- 3. Check seals: Ensure all internal seals and gaskets in the cyclone are present and correctly seated.
- 4. Adjust usage: Avoid using the cordless vacuum for heavy construction dust; use a dedicated shop vac instead.
- 5. Replace cyclone: If damage is found, replace the cyclone assembly to restore proper dust separation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Cyclone Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements