E03
Beko Airflow Restriction / Blocked Duct Fault

Cordless vacuum displays E03 and suction is very weak or absent, motor may sound strained or change pitch frequently.

Advertisements

Possible Causes

Clogged dust bin cyclone assembly, Blocked wand or extension tube, Obstructed inlet at floor nozzle, Severely clogged pre-motor filter

How to Fix / Troubleshooting

Safety first: Switch OFF and remove the battery pack before clearing blockages.

  • 1. Empty the dust bin: Remove the bin from the main body and empty it completely. Tap the sides to dislodge compacted dust from the cyclone shroud.
  • 2. Inspect the cyclone: Remove the cyclone unit (if detachable on your Beko model). Look for clumps of dust or foreign objects inside the cyclone cones and at the mesh shroud. Use a soft brush to clean thoroughly.
  • 3. Check the wand and tools: Detach the wand and any tools. Push a flexible rod or broom handle gently through the wand to clear any blockage. Inspect the crevice tool and upholstery tools for obstructions.
  • 4. Clean the pre-motor filter: Remove the pre-motor filter from behind or above the dust bin. Tap off dust or wash if the manual allows. Ensure it is completely dry before refitting to avoid motor damage.
  • 5. Inspect the floor nozzle: Look into the suction channel of the motorised head. Remove any large debris, hair clumps, or objects lodged near the brushroll or neck.
  • 6. Reassemble and test: Refit all components and the battery. Run the vacuum on normal mode. If E03 persists with clear airflow, the airflow sensor or main PCB may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cyclone Assembly
Check Price on Amazon

We may earn a commission from links on this page.