F1
Bissell Nozzle LED / Accessory Power Fault

Cordless vacuum shows F1 and the LED headlight flickers or does not turn on

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged wiring harness in floor nozzle, Loose connector between nozzle and wand, Failed LED board, Faulty accessory power output on main PCB

How to Fix / Troubleshooting

Safety first: Remove the battery before inspecting electrical connectors.

  • Check connections: Detach the floor nozzle from the wand and inspect the electrical contacts. Clean any dust or debris and ensure the connectors are not bent or corroded.
  • Inspect wiring: Look along the wand and into the nozzle neck for pinched or broken wires. If the wand harness is visibly damaged, replace the wand assembly.
  • Test without nozzle: Run the vacuum without the nozzle attached. If F1 disappears, the fault is likely in the nozzle LED board or wiring.
  • Replace nozzle assembly: On most Bissell cordless models, the LED board is integrated into the nozzle and not separately serviceable. Replace the complete floor nozzle if the LED or wiring is faulty.
  • Main PCB check: If multiple nozzles show the same F1 fault, the accessory power output on the main control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Floor Nozzle Assembly
Check Price on Amazon