CHG
Black+Decker
Charging Fault / Charger-Battery Mismatch
Display shows 'CHG' flashing or charger LED blinks rapidly and vacuum will not charge
Advertisements
Possible Causes
Using incorrect charger model, Charger output failure, Battery pack voltage out of range, Battery pack protection circuit open
How to Fix / Troubleshooting
Safety first: Unplug the charger from the mains before inspection.
- Confirm charger model: Check that the charger part number matches the one specified for your Black+Decker cordless vacuum model and battery voltage.
- Inspect charger and cable: Look for damage, frayed cords, or burn marks. Do not use a damaged charger.
- Try another outlet: Plug the charger into a different wall outlet to rule out power issues.
- Test with another battery: If you have another compatible battery, try charging it. If only one battery fails to charge, that pack is likely defective.
- Replace faulty component: Replace the charger if it fails with multiple batteries. Replace the battery pack if it is the only one that will not charge and triggers CHG error.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Battery Charger