Possible Causes

Worn or stuck trigger microswitch, Broken trigger lever, Loose wiring to trigger on main PCB

How to Fix / Troubleshooting

Safety first: Remove the battery before inspecting the trigger area.

  • Check trigger movement: Squeeze and release the trigger several times. It should move smoothly and spring back.
  • Inspect for debris: Look around the trigger for dust or foreign objects that may prevent full travel. Clean with a soft brush.
  • Listen for click: With the battery removed, slowly pull the trigger and listen for a faint click from the microswitch. No click suggests a failed switch.
  • Professional replacement: Replacing the trigger switch usually requires opening the main housing and desoldering the old switch. Have this done by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Trigger Microswitch