F5
Black+Decker
Battery Fuel Gauge / Sensing Fault
Vacuum shows 'F5', battery indicator behaves erratically (jumping from full to empty)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty battery pack sense line, Damaged battery management IC, Loose connector between battery and PCB, Non-genuine battery without proper communication
How to Fix / Troubleshooting
Safety first: Remove the battery before inspection.
- Clean and reseat battery: Wipe contacts and reinstall the battery firmly until it clicks.
- Try another battery: If available, test with a genuine Black+Decker battery. If the gauge behaves normally, replace the original pack.
- Reset electronics: With the battery removed, hold the trigger for 10–15 seconds, then reinstall the battery and test.
- Service if persistent: If F5 appears with multiple batteries, the main PCB's sensing circuit is likely faulty and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Lithium-Ion Battery Pack / Main Control PCB