F2
Bomann Airflow Blockage / Cyclone Restriction

Vacuum pulses on and off rapidly, F2 or blockage icon appears, suction fluctuates

Advertisements

Possible Causes

Blockage in extension tube, Blocked inlet at dust bin, Large object stuck in floor nozzle neck, Collapsed flexible hose (if equipped)

How to Fix / Troubleshooting

Safety first: Switch OFF the vacuum and remove the battery pack before clearing any blockages.

  • Step 1 – Remove accessories: Detach the floor nozzle, wand, and any hose from the main body.
  • Step 2 – Check each section: Look through the wand and hose against a light source. Use a long, blunt rod to gently push out any clogs. Do not use sharp objects.
  • Step 3 – Inspect floor nozzle neck: Look into the neck of the motorized floor head where it connects to the wand. Remove any debris or objects lodged there.
  • Step 4 – Check dust bin inlet: Inspect the opening where dirt enters the dust bin. Clear any buildup or stuck objects.
  • Step 5 – Reassemble and test: Reconnect components one at a time, testing suction after each to identify any remaining restriction.

If F2 persists with all airways clear, the pressure sensor or control PCB may be misreading airflow and should be checked by a technician.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Extension Tube
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements