Bomann Nozzle LED Light Failure

LED lights on the floor nozzle do not turn on, but the brush roll still spins

Advertisements

Possible Causes

Burned-out LED strip in floor head, Broken wire inside nozzle, Loose connector between wand and nozzle, Faulty LED driver circuit on nozzle PCB

How to Fix / Troubleshooting

Safety first: Remove the battery pack and disconnect the floor nozzle before inspection.

  • Step 1 – Check connections: Inspect the electrical contacts between the wand and nozzle. Clean with a dry cloth.
  • Step 2 – Wiggle test: With the vacuum running (battery installed), gently move the wand-nozzle connection and see if LEDs flicker. Then power off and remove the battery.
  • Step 3 – Inspect LED cover: Check for cracks or moisture inside the LED lens area. Moisture can damage LEDs.

If the brush works but LEDs never light, the LED strip or nozzle PCB is likely faulty. Replace the entire motorized floor nozzle or have the LED assembly serviced if available as a separate part.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Motorized Floor Nozzle (LED Assembly)