F2
Bosch Filter Clogged Warning

Display shows F2, filter icon illuminated, suction reduced

Advertisements

Possible Causes

Pre-motor filter heavily clogged with fine dust, HEPA/post-motor filter saturated, Use without regular filter maintenance, Vacuuming of plaster or fine construction dust

How to Fix / Troubleshooting

Safety first: Remove the battery before handling filters. Avoid inhaling dust when cleaning.

  • Clean pre-motor filter: Remove the pre-motor filter and tap it gently against a hard surface outdoors to dislodge dust. If washable, rinse under lukewarm water until clear. Do not use detergents or brushes that can damage the media.
  • Dry completely: Allow washable filters to air dry for at least 24 hours. Never reinstall a damp filter; this can damage the motor and promote mold.
  • Replace HEPA filter: If the HEPA/post-motor filter is dark, deformed, or has been in use for more than the recommended interval, replace it with a genuine Bosch filter.
  • Avoid fine dust: Do not use the vacuum for large amounts of fine construction dust; this clogs filters quickly and can damage the motor.
  • Reset indicator: Some models require a manual reset of the filter indicator (e.g., holding a button). Follow the user manual to clear F2 after maintenance.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Pre-Motor Filter and HEPA Filter
Check Price on Amazon