F5
Bosch Mode Selector / Control Logic Error

Display shows F5, vacuum beeps and stops when switching power modes

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty mode selector button, Stuck electronic switch on PCB, Firmware glitch, Contaminated button contacts

How to Fix / Troubleshooting

Safety first: Remove the battery before working on the handle or controls.

  • Button exercise: Press the mode button(s) repeatedly 20–30 times with the battery removed to help clear minor oxidation or debris.
  • Clean exterior: Wipe around the buttons with a slightly damp cloth (water only) and dry thoroughly. Do not allow liquid to enter the housing.
  • Power reset: Reinsert the battery and hold the power/mode button combination specified in the manual to reset the electronics, if available.
  • Inspect if accessible: If you can remove the handle cover, check that the rubber button caps are not misaligned and that the tactile switches on the PCB click properly.
  • Replace handle/PCB: If F5 persists and buttons do not respond reliably, the control PCB or handle assembly should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Handle Control Panel / PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements