Bush Air Leak / Blocked Filters

Cordless vacuum has very weak suction even though the motor sounds normal and there are no error codes.

Advertisements

Possible Causes

Clogged pre-motor filter, Clogged HEPA filter, Damaged or missing bin seal, Cracked cyclone assembly

How to Fix / Troubleshooting

Safety first: Remove the battery before cleaning filters or inspecting seals.

  • Empty the bin: Release and empty the dust container. Tap it gently to remove compacted dust.
  • Clean or replace filters: Remove pre-motor and HEPA filters. Clean or wash them according to the Bush manual. Replace filters that are torn, deformed, or permanently dirty.
  • Inspect seals: Check the rubber gasket around the bin lid and where the bin connects to the main body. If the seal is cracked, flattened, or missing, unfiltered air will leak in and reduce suction. Replace the seal or bin assembly if necessary.
  • Check for cracks: Inspect the cyclone and bin for hairline cracks. Cracks can cause loss of suction. Replace the cyclone/bin assembly if damaged.
  • Test suction at the main inlet: Remove the wand and floorhead and test suction directly at the main body inlet. If suction is strong there but weak at the floorhead, the issue is in the wand or floorhead, not the main unit.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Dust Bin & Cyclone Assembly
Check Price on Amazon

We may earn a commission from links on this page.