Possible Causes

Aged lithium cells with high internal resistance, Battery stored long-term at low charge, Repeated high-temperature use, Manufacturing defect in battery pack

How to Fix / Troubleshooting

Safety: Stop using the battery if it becomes hot, swollen, or emits odor.

  • Recalibrate (optional): Perform 1–2 full discharge/charge cycles as described in the manual.
  • Measure runtime: Time how long the vacuum runs in Eco/Normal mode with a clean filter and no blockages.
  • Replace battery: If runtime is far below the specification (e.g., less than 20–30% of rated time), replace the battery with an original Dreame pack.

Do not attempt to rebuild or open the battery pack yourself.