E8
Electrolux
High-Power Mode Current Limit / Overload
Vacuum runs only at low power, turbo mode not available, E8 appears when trying to switch to high power.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partially clogged filters, Restricted airflow in wand or nozzle, Weak battery unable to supply high current, Failing main motor drawing excess current
How to Fix / Troubleshooting
Safety first: Turn OFF the vacuum and remove the battery before cleaning.
- Clean all filters: Remove and clean pre-motor and HEPA/post-motor filters as per the user manual. Ensure they are completely dry before reinstalling.
- Check for blockages: Detach the wand and nozzle. Inspect the wand tube, nozzle neck, and brushroll chamber for obstructions. Remove any debris.
- Test with fully charged battery: Charge the battery to 100%. Install it and test turbo mode with the wand and nozzle removed. If turbo works on the handheld unit alone, the restriction is in the wand/nozzle.
- Evaluate battery health: If turbo mode still triggers E8 and the runtime is short, the battery may be weak. Try a new or known-good battery.
- Motor or PCB fault: If a good battery and clean airflow path still cause E8, the motor or control PCB may be limiting current due to internal faults. Professional diagnosis is recommended.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Suction Motor Assembly
Check Price on Amazon
We may earn a commission from links on this page.