ETA
Intermittent Electrical Connection in Wand
Cordless vacuum intermittently cuts out when the wand is moved or twisted.
Advertisements
Possible Causes
Broken internal wire in wand harness, Loose wand connectors, Cracked solder joints in wand terminals, Excessive strain on wand cable
How to Fix / Troubleshooting
Safety first: Remove the battery before inspecting the wand.
- Re-seat connections: Disconnect and reconnect the wand at both ends several times to clean contacts and ensure a tight fit.
- Flex test: With the vacuum running (battery installed), gently move the wand while observing for cut-outs. Stop immediately if arcing or heat is detected.
- Replace wand if faulty: If movement consistently causes power loss, the internal wiring is likely damaged.
When to call a technician: Replace the wand with an original ETA part. Internal rewiring is not recommended for safety reasons.