Eufy
Thermal Cutoff or Battery Voltage Sag
Vacuum shuts off after a few seconds of use without showing an error code.
Advertisements
Possible Causes
Overheated motor from previous use, Severely clogged filters, Aged battery with high internal resistance, Blocked air vents
How to Fix / Troubleshooting
Safety first: Turn OFF the vacuum and remove the battery.
- Allow cooling: Let the vacuum and battery rest for at least 30 minutes in a cool, dry place.
- Clean filters and airflow path: Remove and clean all filters, empty the bin, and clear any blockages in the cyclone, wand, and head.
- Inspect vents: Ensure the motor exhaust vents are not covered by dust or lint. Clean with a dry brush.
- Test on low power: Reinstall the battery and run the vacuum on the lowest power setting. If it still shuts off quickly, the battery may be failing.
- Try a new battery: If available, test with a new or known-good Eufy battery pack. Replace the battery if runtime remains very short.
Advertisements
Repair Difficulty
Easy
2/5