Tool Start / Bluetooth Communication Fault
Vacuum stops and displays E05 when used with a connected cordless tool via Bluetooth or remote
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Interference or weak Bluetooth signal, Low battery in remote or tool module, Faulty Bluetooth receiver module in vacuum, Firmware incompatibility between modules
How to Fix / Troubleshooting
Safety first: Switch OFF the vacuum and remove the battery before handling internal components.
- 1. Check remote or tool module battery: If using a Festool Bluetooth remote or tool module, replace its coin cell or internal battery as specified by Festool.
- 2. Reduce interference: Ensure there are no large metal objects or strong RF sources (welders, large motors, Wi-Fi routers very close) between the vacuum and the tool/remote. Operate within the recommended range.
- 3. Re-pair Bluetooth devices: Follow the Festool pairing procedure: clear existing pairings on the vacuum, then re-pair the remote or tool module. Confirm that the pairing LED indications match the manual.
- 4. Test manual start: Start the vacuum using its main switch only. If it runs normally without E05, the fault is limited to the Bluetooth control path.
- 5. Inspect Bluetooth receiver module: If E05 persists even after re-pairing and replacing remote batteries, the internal Bluetooth receiver module or its wiring may be defective. This module is typically mounted near the control electronics and should be replaced as a unit by a service center.