Gorenje Air Leak / Poor Sealing

Dust and debris leak from around the dust container or from joints in the wand during use.

Advertisements

Possible Causes

Damaged dust container gasket, Cracked dust bin, Loose wand connections, Missing or worn O-rings on joints

How to Fix / Troubleshooting

Safety: Turn OFF the vacuum and remove the battery.

Check seals and joints:

  • Inspect the rubber gasket around the dust container lid and where it meets the main body. Replace if torn or flattened.
  • Check the dust container for cracks.
  • Inspect wand and accessory joints for missing O-rings or locking tabs.

Replace damaged seals or components with genuine Gorenje parts to restore proper sealing and suction.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Dust Container Seal
Check Price on Amazon

We may earn a commission from links on this page.