Possible Causes
Severely clogged filters, Blocked air path in wand or nozzle, Failing main motor drawing high current, Battery unable to supply required current
How to Fix / Troubleshooting
Safety: Remove the battery.
Clear restrictions:
- Clean or replace all filters.
- Check the wand, hose (if present), and nozzle for blockages and remove any obstructions.
Battery check:
- Fully charge the battery and test again.
- If possible, test with another battery to rule out battery issues.
If the vacuum still shuts off quickly with clear airflow and a good battery, the motor or control electronics may be faulty and require professional repair.