E15
Groupe SEB Storage Lock / Deep Discharge Protection

Cordless vacuum displays E15 and refuses to start after being stored for a long period.

Advertisements

Possible Causes

Battery voltage below safe threshold, Long-term storage without charging, Internal protection fuse in battery tripped, Aged cells with high internal resistance

How to Fix / Troubleshooting

Safety: Inspect the battery for swelling, leaks, or cracks. If any are present, do not use the battery.

  • Attempt recovery charge: Place the battery on the original charger and leave it connected for several hours, even if LEDs do not light immediately.
  • Check charger output: Ensure the charger LED is on and the outlet is working.
  • Do not use third-party chargers: They may not correctly handle protection circuits.
  • If still locked: The battery's internal protection may have permanently disabled the pack. Replace with a new Groupe SEB battery.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Battery Pack
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements