F2
Hoover Filter Not Fitted / Filter Sensor Error

Cordless vacuum shows F2 and will not start; often after cleaning filters

Advertisements

Possible Causes

Pre-motor filter missing or not seated, Wet filter installed, Faulty filter presence sensor, Wrong filter type fitted

How to Fix / Troubleshooting

Safety first: Remove the battery before handling filters.

Steps:

  • Check filter presence: Open the filter compartment and confirm the correct Hoover filter is installed in the right orientation.
  • Ensure filter is dry: If you recently washed the filter, it must be completely dry (24 hours minimum). A damp filter can trigger errors and damage the motor.
  • Clean seating area: Remove dust from the filter housing and sensor area so the filter can sit flat and actuate any internal switch or magnet sensor.
  • Refit firmly: Press the filter into place until it is fully seated and any cover is latched.

If F2 persists: The filter sensor (mechanical or magnetic) may be faulty. Use a genuine replacement filter; if the error remains, the sensor or main PCB will need professional attention.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Hoover Pre-Motor Filter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements