E15
Kärcher
Mode Button / User Interface Error
Cordless vacuum shows E15 and cannot switch between power modes
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or damaged mode button, Contamination under keypad, Faulty user interface PCB, Broken ribbon cable between UI and main PCB
How to Fix / Troubleshooting
Safety first: Remove the battery before working near the controls.
- Check button travel: Press the mode button repeatedly with the unit off. It should move freely and return smoothly. If it feels stuck, debris may be lodged around it.
- Clean around button: Use a soft brush or compressed air to remove dust from around the button. Do not spray liquids directly into the control panel.
- Inspect for cracks: Look for cracks in the control panel that could allow dirt or moisture inside.
- Internal inspection (advanced): If comfortable, remove the housing screws and gently open the handle area to inspect the UI PCB and ribbon cable. Ensure connectors are fully seated.
- Replace UI module: If the button or UI PCB is physically damaged, replace the user interface assembly with an original Kärcher part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface PCB / Control Panel
Check Price on Amazon
We may earn a commission from links on this page.