E7
Levoit Brushroll Motor Communication / Driver Error

Vacuum displays E7 and the brushroll will not spin, though suction works

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose connection in floor head wiring harness, Damaged brushroll motor driver on main PCB, Broken contacts in wand power terminals, Faulty brushroll motor

How to Fix / Troubleshooting

Safety first: Remove the battery pack before disconnecting the wand or floor head.

  • Check wand connections: Detach the wand from the main body and floor head. Inspect the electrical contacts at both ends for dirt or oxidation. Clean gently with a dry cloth.
  • Inspect for damage: Look for cracks in the wand or exposed wires. If the wand is bent or damaged, replace it.
  • Test direct connection (if design allows): Some Levoit models allow the floor head to connect directly to the main body without the wand. Try this configuration; if the brushroll works, the wand wiring is faulty.
  • Check floor head contacts: Inspect the contacts on the floor head neck. Clean and ensure they spring back properly.
  • If E7 persists with all configurations: The brushroll motor or control electronics are likely faulty. Replace the motorized floor head or have the main PCB inspected by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Wand Assembly with Power Terminals
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements