Levoit Complete Power Loss

Vacuum will not turn on at all; no lights, no beeps

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Battery pack fully discharged or failed, Battery not latched into handle, Faulty main power switch, Internal fuse or main PCB failure

How to Fix / Troubleshooting

Safety first: Do not attempt to open the battery pack or bypass fuses.

  • Check battery installation: Remove and firmly reinstall the battery until it clicks into place.
  • Charge battery: Place the vacuum or battery on the charger for at least 3 hours. Confirm that charging indicators light up.
  • Try another outlet and charger: Use a known‑good outlet and, if available, a second Levoit charger.
  • Test power switch: Press and hold the power button for 3–5 seconds. Try any trigger lock or mode buttons per the user manual.
  • If still dead with a known‑good battery: The main PCB, internal fuse, or wiring is likely faulty. Professional diagnosis and main body repair or replacement are required.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon